track Technical - Stafford Bridge Doors

In this section of the Stafford Bridge website you will find various aspects of testing and certification in the forms of technical data, testing video footage and performance reference charts.

The nature of the testing allows Stafford Bridge to build products that are suitable for a specific protective requirements such as high security doorsets only. However, at Stafford Bridge multi-functional testing and product design does not only deliver the required protection that individual products such as high security doorsets, bullet resistant doorsets and blast resistant doorsets need to achieve but can also be built so that the individual performance of security, ballistic and blast criteria can be built into one doorset providing protection for all. Three solutions one product.
This capability is extended even further with an extensive test portfolio of fire door protection which Stafford Bridge has developed over the many years of testing.

The same principle is being adopted with the development and testing of a range of high security windows, bullet resistant windows and blast resistant windows. Please contact the sales/technical department for further information.
For more specific door performance information please also review the individual door data sheets found in the products section of this website.


Louvre Testing Video

Multi Testing Video

Blast Testing Video

Doorset Performance Chart

DOOR      TYPE min thickness leaf weight interior exterior   SECURITY FIRE                                                      BS 476 pt 22   BALLISTIC                  BS EN 1522 BLAST                      'Protected Spaces' ACCOUSTIC
BS EN ISO 717-1
  (mm) (kg.m-2)       LPCB FD30 FD60  FD90 FD120 FD180 FD240 FB1 FB4 FB6 FB7 C25 C15 (RwdB)
BEDFORD 44 varies Y Y   - Y Y - - -   - - - - Y - 34**
PAVENHAM 44 varies Y Y   - Y - - - -   - - - - - - -
HENDON 46 38 Y Y   LPS SR2 Y Y - - -   Y - - - Y - 34**
SANDHURST 54 45 Y Y   LPS SR3 Y Y - - -   Y - - - Y - 36**
WILTON 54 69 Y Y   LPS SR4 Y Y - - -   Y Y Y Y Y Y 40
HALTON 56 85 Y Y   LPS SR4 Y Y Y Y Y   Y Y Y Y Y Y 40
WHITEHALL 55 77 Y Y   - Y Y - - -   Y Y Y Y Y Y 40
SECLUSION 54 45 Y -   - Y - - - -   - - - - - - n/a
  ** estimated

Fire Certification Chart

Fire Certification Chart
Doorset Name FD30
  SINGLE   DOUBLE
  H   W   H   W
HENDON & 2520 x 1334   2428 x 2474
SANDHURST 3079 x 1055   2770 x 2130
               
WILTON 2168 x 1106   2168 x 2128
2268 x 1056   2268 x 2010
               
HALTON 2218 x 1156   2218 x 2288
2318 x 1086   2318 x 2088
               
WHITEHALL 2168 x 1006   2168 x 1928

 

 

  FD60
  SINGLE   DOUBLE
  H   W   H   W
HENDON & 2130 x 1139   2068 x 2116
SANDHURST 2599 x 904   2339 x 1828
               
WILTON 2118 x 1056   2118 x 2028
2218 x 1006   2218 x 1928
               
HALTON 2168 x 1106   2168 x 2128
2268 x 1036   2268 x 1988
               
WHITEHALL 2168 x 1006   2168 x 1928

 

 

  FD90
  SINGLE   DOUBLE
HALTON H   W   H   W
2168 x 1006   2168 x 1928
               
  FD180
  SINGLE    
HALTON FB6 H   W        
2410 x 1080        
               
  FD240
          DOUBLE
HALTON FB6         H   W
        2740 x 2554
Larger doors may be available subject to assessment     
by UKAS accredited  fire consultant